Heat Soaked Safety Glass
Invercargill, New Zealand
- 380.6K profile views
- 46 saves
During float glass manufacture, impurities in the glass batch can result in inclusions in the finished product. These inclusions are so small that they are normally invisible to the naked eye and yet they can cause spontaneous breakage in Toughened Safety Glass.
The most notorious of these inclusions is nickel sulphide (NiS) crystals (stones), which can be contained in the raw material during the production of the glass.
The glass toughening process requires the glass to be heated to just below its softening point and then rapidly cooled. Because this heating and rapid cooling process induces substantial tension in the glass, nickel sulphide stone inclusions in the tension core can cause spontaneous breakage, as they are known to change phase (expand) some time after the toughening process.
Heat soak testing is a secondary process that can be applied to the Toughened units after initial processing. Heat soaking reduces the incidence of Toughened Safety Glass breaking spontaneously after installation by triggering prone panels before they are installed, meaning only the lower risk units ever make it to site. This therefore reduces the associated replacement, maintenance and disruption costs and the risk of the building being classified as unsafe.
Product Details
- Product
- Heat Soaked Safety Glass
- Category
- Glazing
- Sold by
- Metro Performance Glass
Metro Performance Glass is specified by
Ben Hudson ArchitectsArchitects
Sunday ArchitectsArchitects
MC Architecture StudioArchitects
HB ArchitectureArchitects
Patterson AssociatesArchitects
Young ArchitectsArchitects
Daniel Marshall ArchitectsArchitects
ArchimediaArchitects
Matter ArchitectsArchitects
MacKay CurtisArchitects
Dalman ArchitectsArchitects
Vila.nzArchitects
Assembly ArchitectsArchitects
South by Southeast ArchitectsArchitects
106 ArchitectsArchitects
Mason & Wales ArchitectsArchitects
Bonnifait + Associates ArchitectsArchitects
Eliška Lewis ArchitectsArchitects
Malcolm Taylor ArchitectsArchitects
Theca ArchitectureArchitects
Johnston ArchitectsArchitects
Leuschke Group ArchitectsArchitects
Ground Up StudioArchitects
Glamuzina ArchitectsArchitects
ObjectsArchitectural Designers
Walker ArchitectureArchitectural Designers
ao architectureArchitectural Designers
Craftsman CabinetsCarpenters & Cabinetmakers
Lite HouseBuilders
Cogan Custom HomesBuilders
Altus® Window SystemsJoinery Installers & Repairs
Jason Frater BuildersBuilders
Iconic Construction | Iconic 3DConstruction
staceyfarrell.comArchitecture & Design
Urbanfunction ArchitectureArchitectural Designers
Craig Finnie BuildersBuilders
eHausDesign & Build
Honour CreativeInterior Designers
LAD ArchitectureArchitectural Designers
Slate ConstructionDesign & Build
Creative ArchArchitectural Designers
Josephine DesignInterior Designers
Lewis BuildBuilders
HawkinsConstruction
Anderson ArchitectureArchitectural Designers
Narley ConstructionBuilders
Arcline ArchitectureArchitectural Designers
Mark Scowen PhotographyPhotographers
Arc AtelierArchitectural Designers
ataArchitectural Designers
Design With PNCInterior Designers
Threefold ArchitectureArchitectural Designers
Home ProjectsBuilders
M C Fearnley DesignArchitectural Designers
White Wood HomesBuilders
Ainsworth & CollinsonBuilders
Beck BuildingBuilders
Weir ArchitectureArchitectural Designers
HWA LtdArchitectural Designers
Build ThisBuilders
During float glass manufacture, impurities in the glass batch can result in inclusions in the finished product.
These inclusions are so small that they are normally invisible to the naked eye and yet they can cause spontaneous breakage in Toughened Safety Glass.
The most notorious of these inclusions is nickel sulphide (NiS) crystals (stones), which can be contained in the raw material during the production of the glass.
The glass toughening process requires the glass to be heated to just below its softening point and then rapidly cooled. Because this heating and rapid cooling process induces substantial tension in the glass, nickel sulphide stone inclusions in the tension core can cause spontaneous breakage, as they are known to change phase (expand) some time after the toughening process.
Heat soak testing is a secondary process that can be applied to the Toughened units after initial processing. Heat soaking reduces the incidence of Toughened Safety Glass breaking spontaneously after installation by triggering prone panels before they are installed, meaning only the lower risk units ever make it to site. This therefore reduces the associated replacement, maintenance and disruption costs and the risk of the building being classified as unsafe.
Downloads
Downloads (4)4 Direct downloads • 6 Available on request
Frequently asked questions about
Heat Soaked Safety Glass
The Heat Soaked Safety Glass is supplied by Metro Performance Glass. It is also on their website, and you can browse every product Metro Performance Glass lists on ArchiPro.
Metro Performance Glass does not publish a price for the Heat Soaked Safety Glass on ArchiPro. for pricing, or visit their website.
It is listed under Glazing on ArchiPro, where you can compare it with glazing from other suppliers.
Yes. Metro Performance Glass provides scope documents and BPIR for it, in the Downloads section above, alongside an ArchiPro spec sheet. More of their files are on their downloads page.
from this page, see their contact details on ArchiPro, or visit their website. The Metro Performance Glass profile on ArchiPro has the rest of their products.
More products from
Metro Performance Glass
The rest of this range, and everything else Metro Performance Glass makes.
More in
Glazing
Everything else in Glazing, from every supplier on ArchiPro.